{"product_id":"metacaulk-intumescent-pipe-collars-4-case-of-6","title":"Metacaulk Intumescent Pipe Collars 4\" - Case of 18","description":"\u003ch2\u003eMetacaulk Pipe Collars\u003c\/h2\u003e\n\u003cp\u003eMetacaulk Pipe Collars are prefabricated firestop devices designed for open and closed through-penetration firestop systems using 1-1\/2 to 6 inch (38–152 mm) plastic pipes. They provide reliable fire protection by helping seal plastic pipe penetrations and prevent the spread of flames, smoke, and heat through fire-rated assemblies.\u003c\/p\u003e\n\u003cp\u003eFeaturing an easy lock mechanism and an efficient collar design, Metacaulk Pipe Collars help reduce installation time and labor costs compared to traditional collar systems. They are suitable for sealing plastic pipes in both closed and vented (DWV) conditions and can be used in approved concrete, gypsum wall, and wood floor assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePrefabricated firestop collar for plastic pipe penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for 1-1\/2 to 6 inch (38–152 mm) plastic pipes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for open and closed through-penetration firestop systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEasy lock mechanism for fast and secure installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduces installation time by up to 25%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo measurement of material required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHighly intumescent material expands during fire exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTested for PVC, CPVC, ABS, PVC\/ABS Foam Core, FRPP, and PP pipe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUL classified for both open and closed pipe systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFBC System Compatible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFits in limited access areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEconomical solution that helps reduce labor costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePVC pipe penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCPVC pipe penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eABS pipe penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePVC\/ABS Foam Core pipe penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFRPP pipe penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePP pipe penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePEX pipe applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical cable penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClosed pipe systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVented DWV (drain, waste, and vent) systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConcrete floor and wall assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGypsum wall assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWood floor assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial construction projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlumbing penetrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFire-rated wall systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFire-rated floor systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlastic pipe firestop applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProjects requiring quick and efficient installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Fire Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMetacaulk Pipe Collars expand when exposed to fire to help seal plastic pipe penetrations and maintain the integrity of fire-rated assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFast \u0026amp; Easy Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe prefabricated collar design and easy lock mechanism simplify installation while reducing labor time compared to traditional firestop collar systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for use with multiple plastic pipe materials, including PVC, CPVC, ABS, PVC\/ABS Foam Core, FRPP, PP, and approved PEX applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCost-Effective Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe collar design eliminates material measurement and reduces installation effort, helping lower overall project costs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSurface Preparation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the penetration area is clean and free from dust, debris, and loose materials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify pipe size, material, and assembly requirements match the approved firestop system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm compatibility with the rated wall or floor assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Instructions\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eSelect the appropriate Metacaulk Pipe Collar size for the pipe diameter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the collar around the plastic pipe penetration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the collar using the integrated locking mechanism.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify proper installation according to the tested firestop system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the completed installation meets applicable firestop requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInstall only according to tested and approved firestop systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow manufacturer installation instructions and applicable building codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNot intended for environments with long-term exposure to rainfall or saltwater spray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify compatibility with the specific pipe type and rated assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMetacaulk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated intumescent pipe collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eOpen and closed through-penetration firestop systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Pipe Materials\u003c\/td\u003e\n\u003ctd\u003ePVC, CPVC, ABS, PVC\/ABS Foam Core, FRPP, PP, PEX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe Size Range\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 to 6 inches (38–152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Assemblies\u003c\/td\u003e\n\u003ctd\u003eUp to 3-hour concrete floors\/walls, up to 2-hour gypsum walls, up to 2-hour wood floors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Feature\u003c\/td\u003e\n\u003ctd\u003eEasy lock mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClassification\u003c\/td\u003e\n\u003ctd\u003eUL classified for open and closed pipe systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eFBC System Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Weight\u003c\/td\u003e\n\u003ctd\u003e7.21 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Dimensions\u003c\/td\u003e\n\u003ctd\u003eHeight: 1.75 in × Length: 7.75 in × Width: 21.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e021449663519\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterleaved\u003c\/td\u003e\n\u003ctd\u003e10021449663516\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. What are Metacaulk Pipe Collars?\u003c\/strong\u003e\u003cbr\u003eMetacaulk Pipe Collars are prefabricated firestop devices designed to protect plastic pipe through-penetration systems in fire-rated assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. What pipe sizes are compatible with Metacaulk Pipe Collars?\u003c\/strong\u003e\u003cbr\u003eThey are designed for use with plastic pipes ranging from 1-1\/2 to 6 inches (38–152 mm) in diameter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. Where are Metacaulk Pipe Collars used?\u003c\/strong\u003e\u003cbr\u003eThey are used in open and closed through-penetration firestop systems in fire-rated concrete floors, walls, gypsum walls, and wood floor assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. How do Metacaulk Pipe Collars provide fire protection?\u003c\/strong\u003e\u003cbr\u003eThe highly intumescent material expands during fire exposure to help seal plastic pipe penetrations and prevent the spread of flames, smoke, and heat.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. Why choose Metacaulk Pipe Collars?\u003c\/strong\u003e\u003cbr\u003eThey provide a fast, prefabricated, and reliable firestop solution that simplifies installation and protects plastic pipe penetrations in rated assemblies.\u003c\/p\u003e\n\u003c!----\u003e","brand":"Metacaulk","offers":[{"title":"Default Title","offer_id":45301350629550,"sku":"66351","price":184.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8396\/6382\/files\/9a6f819f-1c36-4cc1-8def-6ce433585b59.png?v=1794422481","url":"https:\/\/www.diamondtoolstore.com\/products\/metacaulk-intumescent-pipe-collars-4-case-of-6","provider":"Diamond Tool Store","version":"1.0","type":"link"}