{"product_id":"sc-90-clear-coat","title":"SC 90 Clear Coat","description":"\u003ch2\u003eSC 90 Clear Coat — High-Performance 90% Solids Aliphatic Polyaspartic Floor Coating\u003c\/h2\u003e\n\u003cp\u003eSC 90 Clear Coat is a two-component, high-solids, low-odor, solvent-based aliphatic polyaspartic coating engineered for fast-cure, durable protection of concrete floors in demanding industrial and commercial environments. Formulated with 90% solids content, it delivers a high-gloss, non-yellowing finish with excellent abrasion, impact, and chemical resistance. Designed for contractors and applicators who require rapid return to service with minimal downtime, it is suitable for both direct-to-concrete applications and as a topcoat over broadcast systems. It can also be pigmented to meet project-specific aesthetic requirements.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating Type\u003c\/td\u003e\n\u003ctd\u003eTwo-component aliphatic polyaspartic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolids Content\u003c\/td\u003e\n\u003ctd\u003e90% (±2%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eHigh gloss (\u0026gt;90 at 60° per ASTM D523)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOC Content\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50 g\/L (low odor\/VOC compliant in most regions; OTC compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColors Available\u003c\/td\u003e\n\u003ctd\u003eClear (non-yellowing); pigmented options available upon request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMix Ratio (by volume)\u003c\/td\u003e\n\u003ctd\u003e1.7:1 (Part A : Part B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePot Life (100g mass @ 77°F \/ 25°C)\u003c\/td\u003e\n\u003ctd\u003e20–30 minutes (varies with temperature\/mass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViscosity (mixed)\u003c\/td\u003e\n\u003ctd\u003e300–500 cps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Film Thickness\u003c\/td\u003e\n\u003ctd\u003e8–15 mils wet (4–10 mils dry typical per coat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoverage Rate\u003c\/td\u003e\n\u003ctd\u003e100–150 sq. ft. per gallon per coat (depending on surface porosity and thickness; e.g., 150 sq. ft.\/gal at 10 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003e1-gal unit (5 pints Part A + 3 pints Part B); 4.5-gal kit (2.8 gal Part A + 1.7 gal Part B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelf Life\u003c\/td\u003e\n\u003ctd\u003e12 months in unopened containers at 40–90°F (4–32°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Profile Required\u003c\/td\u003e\n\u003ctd\u003eCSP 3–5 (shotblast or diamond grind)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture Vapor Emission Limit\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 lbs\/1,000 sq. ft.\/24 hrs (ASTM F1869) or \u0026lt;75% RH (ASTM F2170)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Temperature\u003c\/td\u003e\n\u003ctd\u003e40–90°F (4–32°C), surface\/ambient, rising; avoid dew point issues\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Stability\u003c\/td\u003e\n\u003ctd\u003eUV-stable, non-yellowing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePigmentable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity (Part A)\u003c\/td\u003e\n\u003ctd\u003e1.09–1.11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Point (Part A)\u003c\/td\u003e\n\u003ctd\u003e94°C (201.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoiling Point (Part A)\u003c\/td\u003e\n\u003ctd\u003e103°C (217.4°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViscosity (Part A)\u003c\/td\u003e\n\u003ctd\u003e100–400 cps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCure Schedule\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStage\u003c\/th\u003e\n\u003cth\u003eTime (@ 77°F \/ 25°C, 50% RH)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTack-free \/ Dry to touch\u003c\/td\u003e\n\u003ctd\u003e1–2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight foot traffic\u003c\/td\u003e\n\u003ctd\u003e4–6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecoat \/ Topcoat window\u003c\/td\u003e\n\u003ctd\u003e4–24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVehicle \/ Heavy traffic\u003c\/td\u003e\n\u003ctd\u003e24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTest Data (7-day cure @ 77°F unless noted)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTest\u003c\/th\u003e\n\u003cth\u003eResult\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Strength (ASTM D638)\u003c\/td\u003e\n\u003ctd\u003e3,500–4,500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElongation (ASTM D638)\u003c\/td\u003e\n\u003ctd\u003e5–15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness Shore D (ASTM D2240, 7 days)\u003c\/td\u003e\n\u003ctd\u003e70–80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressive Strength (ASTM D695, 7 days)\u003c\/td\u003e\n\u003ctd\u003e5,000–6,000 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTaber Abrasion Resistance (ASTM D4060, CS-17 wheel, 1,000 g load, 1,000 cycles)\u003c\/td\u003e\n\u003ctd\u003e20–40 mg loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact Resistance (ASTM D2794)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;50 in-lbs direct \/ \u0026gt;30 in-lbs reverse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexibility (1\/8\" mandrel, ASTM D522)\u003c\/td\u003e\n\u003ctd\u003ePasses (no cracking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesion to Concrete (ACI 503 or similar)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;300 psi (substrate failure typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eSC 90 Clear Coat's aliphatic polyaspartic chemistry delivers UV stability that epoxy-based topcoats cannot match, making it suitable for both interior and exterior applications where yellowing would be unacceptable. Its 90% solids content minimizes shrinkage and solvent off-gassing compared to lower-solids alternatives, while the fast-cure schedule allows same-day return to light foot traffic — a critical advantage in occupied facilities or time-sensitive project schedules.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\n\u003ch4\u003eFast-Cure Formula\u003c\/h4\u003e\n\u003cp\u003eSC 90 Clear Coat reaches tack-free in 1–2 hours and allows light foot traffic in 4–6 hours at 77°F. For contractors working in occupied facilities or on tight schedules, this rapid return-to-service capability reduces project downtime and allows faster project turnover.\u003c\/p\u003e\n\n\u003ch4\u003e90% Solids Content\u003c\/h4\u003e\n\u003cp\u003eAt 90% solids, SC 90 delivers a thick, dense film per coat with minimal volume loss during cure. This high-build characteristic means fewer coats may be required to achieve target dry film thickness, improving application efficiency and reducing labor costs.\u003c\/p\u003e\n\n\u003ch4\u003eUV Stability — Non-Yellowing\u003c\/h4\u003e\n\u003cp\u003eThe aliphatic polyaspartic chemistry provides inherent UV resistance, keeping the coating clear and non-yellowing even under prolonged UV exposure. This makes SC 90 appropriate for exterior applications and interior spaces with significant natural light, where aesthetic longevity is a project requirement.\u003c\/p\u003e\n\n\u003ch4\u003eExceptional Mechanical Strength\u003c\/h4\u003e\n\u003cp\u003eWith compressive strength of 5,000–6,000 psi, tensile strength of 3,500–4,500 psi, and impact resistance exceeding 50 in-lbs direct, SC 90 is engineered to withstand the mechanical demands of warehouses, manufacturing floors, and vehicle traffic areas. Shore D hardness of 70–80 at 7 days confirms a tough, wear-resistant surface.\u003c\/p\u003e\n\n\u003ch4\u003eLow VOC \/ Low Odor\u003c\/h4\u003e\n\u003cp\u003eVOC content is \u0026lt;50 g\/L, making SC 90 compliant in most regions including OTC-regulated areas. The low-odor formulation allows application in occupied or semi-occupied spaces where strong solvent odors would be disruptive or prohibited.\u003c\/p\u003e\n\n\u003ch4\u003ePigmentable\u003c\/h4\u003e\n\u003cp\u003eSC 90 can be pigmented upon request, giving contractors and facility owners flexibility to match floor color requirements or create color-coded zones without switching to a different product system.\u003c\/p\u003e\n\n\u003ch4\u003eExcellent Abrasion and Chemical Resistance\u003c\/h4\u003e\n\u003cp\u003eTaber abrasion loss of only 20–40 mg (CS-17 wheel, 1,000 g, 1,000 cycles) demonstrates outstanding wear resistance for high-traffic surfaces. Combined with the coating's chemical resistance, SC 90 is well-suited for environments exposed to oils, fluids, and cleaning agents.\u003c\/p\u003e\n\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\n\u003ch4\u003eIndustrial and Commercial Floors\u003c\/h4\u003e\n\u003cp\u003eSC 90 is formulated for the abrasion, impact, and chemical resistance demands of industrial and commercial floor environments where durability and fast return to service are critical.\u003c\/p\u003e\n\n\u003ch4\u003eWarehouses and Manufacturing Facilities\u003c\/h4\u003e\n\u003cp\u003eHigh compressive strength and impact resistance make SC 90 appropriate for warehouse floors and manufacturing areas subject to forklift traffic, dropped loads, and heavy equipment.\u003c\/p\u003e\n\n\u003ch4\u003eGarages and Auto Service Areas\u003c\/h4\u003e\n\u003cp\u003eThe coating's resistance to vehicle traffic (cleared for heavy traffic at 24 hours) and chemical resistance to automotive fluids make it a practical choice for garage floors and auto service bays.\u003c\/p\u003e\n\n\u003ch4\u003eTopcoat Over Broadcast Systems (Flake\/Quartz)\u003c\/h4\u003e\n\u003cp\u003eSC 90 is designed to serve as a clear topcoat over decorative broadcast systems, sealing and protecting flake or quartz aggregate while delivering a high-gloss finish.\u003c\/p\u003e\n\n\u003ch4\u003eDirect-to-Concrete Applications\u003c\/h4\u003e\n\u003cp\u003eWhen applied directly to properly prepared concrete profiled to CSP 3–5, SC 90 achieves adhesion exceeding 300 psi with substrate failure typical, ensuring a bond that outlasts the coating itself.\u003c\/p\u003e\n\n\u003ch4\u003eInterior and Exterior UV-Exposed Areas\u003c\/h4\u003e\n\u003cp\u003eThe aliphatic chemistry provides UV stability that makes SC 90 suitable for exterior concrete surfaces or interior areas with significant sunlight exposure where non-yellowing performance is required.\u003c\/p\u003e\n\n\u003ch3\u003eCompatible Materials\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConcrete (properly prepared to CSP 3–5)\u003c\/li\u003e\n\u003cli\u003eBroadcast flake systems (decorative chip\/flake floors)\u003c\/li\u003e\n\u003cli\u003eQuartz broadcast systems\u003c\/li\u003e\n\u003cli\u003ePreviously coated concrete surfaces (within recoat window of 4–24 hours)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eProduct Documents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0551\/8396\/6382\/files\/SC-90-Clear-Coat-Tech-Sheet.pdf?v=1791293219\" target=\"_blank\" rel=\"noopener\"\u003eSC 90 Clear Coat Technical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0551\/8396\/6382\/files\/SC-90-Clear-Coat-SDS.pdf?v=1791293219\" target=\"_blank\" rel=\"noopener\"\u003eSC 90 Clear Coat Safety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplication Instructions\u003c\/h3\u003e\n\n\u003ch4\u003eStep 1: Surface Preparation\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eEnsure concrete is clean, sound, and free of contaminants, laitance, and existing coatings that may inhibit adhesion.\u003c\/li\u003e\n\u003cli\u003eProfile the surface to CSP 3–5 using shotblasting or diamond grinding.\u003c\/li\u003e\n\u003cli\u003eVerify moisture vapor emission is \u0026lt;3 lbs\/1,000 sq. ft.\/24 hrs per ASTM F1869, or \u0026lt;75% RH per ASTM F2170.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch4\u003eStep 2: Mixing\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003ePre-mix each component (Part A and Part B) separately before combining.\u003c\/li\u003e\n\u003cli\u003eCombine at a ratio of 1.7:1 by volume (Part A : Part B).\u003c\/li\u003e\n\u003cli\u003eMix thoroughly for 2–3 minutes using a low-speed drill.\u003c\/li\u003e\n\u003cli\u003eDo not aerate excessively during mixing.\u003c\/li\u003e\n\u003cli\u003eNote: Pot life is 20–30 minutes at 77°F \/ 25°C with a 100g mass; pot life decreases with higher temperatures or larger batch sizes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch4\u003eStep 3: Application\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eConfirm surface and ambient temperatures are between 40–90°F (4–32°C) and rising; avoid application near the dew point.\u003c\/li\u003e\n\u003cli\u003eApply mixed material with a notched squeegee at the recommended wet film thickness of 8–15 mils.\u003c\/li\u003e\n\u003cli\u003eBack-roll immediately with a 3\/8\" nap roller or spiked roller to reduce surface imperfections and release entrapped air.\u003c\/li\u003e\n\u003cli\u003eFor broadcast systems, multiple coats may be required — apply within the recoat window of 4–24 hours.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch4\u003eStep 4: Cleanup\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eClean tools and equipment immediately after use with SpecChem SOLVENT 100, Xylene, toluene, or MEK.\u003c\/li\u003e\n\u003cli\u003eDo not allow material to harden on equipment.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSafety Data Summary\u003c\/h3\u003e\n\n\u003ch4\u003eHazard Information\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Word: Warning\u003c\/li\u003e\n\u003cli\u003eH315: Causes skin irritation\u003c\/li\u003e\n\u003cli\u003eH319: Causes serious eye irritation\u003c\/li\u003e\n\u003cli\u003eH317: May cause an allergic skin reaction\u003c\/li\u003e\n\u003cli\u003eContains flammable components; keep away from open flame, heat, and sparks\u003c\/li\u003e\n\u003cli\u003eFlash Point (Part A): 94°C (201.2°F)\u003c\/li\u003e\n\u003cli\u003eHMIS Health Hazard: 2 (Moderate); Flammability: 1 (Slight); Physical Hazard: 0 (Minimum)\u003c\/li\u003e\n\u003cli\u003eNot for immersion service or areas with constant water pooling\u003c\/li\u003e\n\u003cli\u003ePot life and cure times decrease with higher temperatures or larger mass\u003c\/li\u003e\n\u003cli\u003eFor professional use only; test compatibility in small areas before full application\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003ePersonal Protective Equipment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEye Protection: Safety glasses or goggles required\u003c\/li\u003e\n\u003cli\u003eHand Protection: Chemical-resistant gloves required\u003c\/li\u003e\n\u003cli\u003eRespiratory Protection: Not required in properly ventilated areas; use appropriate respirator if ventilation is inadequate\u003c\/li\u003e\n\u003cli\u003eBody Protection: Appropriate protective clothing for the task being performed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eSafe Handling\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse only outdoors or in a well-ventilated area (P271)\u003c\/li\u003e\n\u003cli\u003eDo not eat, drink, or smoke when using this product (P270)\u003c\/li\u003e\n\u003cli\u003eWash thoroughly after handling (P264)\u003c\/li\u003e\n\u003cli\u003eAvoid breathing dust, fume, gas, mist, vapors, or spray (P261)\u003c\/li\u003e\n\u003cli\u003eKeep away from heat, sparks, and open flame\u003c\/li\u003e\n\u003cli\u003eKeep container closed when not in use; store in a well-ventilated area at 40–90°F (4–32°C)\u003c\/li\u003e\n\u003cli\u003eKeep out of sewers, storm drains, surface waters, and soils in the event of a spill\u003c\/li\u003e\n\u003cli\u003eIf skin contact occurs: wash with plenty of water (P302+P352)\u003c\/li\u003e\n\u003cli\u003eIf eye contact occurs: rinse cautiously with water for several minutes; remove contact lenses if present and easy to do; continue rinsing (P305+P351+P338)\u003c\/li\u003e\n\u003cli\u003eIf skin irritation or rash occurs, seek medical advice\/attention (P333+P313)\u003c\/li\u003e\n\u003cli\u003eIf eye irritation persists, seek medical advice\/attention (P337+P313)\u003c\/li\u003e\n\u003cli\u003eDispose of contents\/container in accordance with local\/regional\/national\/international regulations (P501)\u003c\/li\u003e\n\u003cli\u003eEmergency telephone: VelocityEHS 1-800-255-3924 (North America)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What surface profile is required before applying SC 90 Clear Coat?\u003c\/strong\u003e\u003cbr\u003eA: Concrete must be profiled to CSP 3–5, achieved by shotblasting or diamond grinding. The surface must also be clean, sound, and meet moisture vapor emission limits of \u0026lt;3 lbs\/1,000 sq. ft.\/24 hrs (ASTM F1869) or \u0026lt;75% RH (ASTM F2170).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How long before the floor can be returned to service after application?\u003c\/strong\u003e\u003cbr\u003eA: At 77°F \/ 25°C and 50% RH, SC 90 is tack-free in 1–2 hours, allows light foot traffic in 4–6 hours, and is ready for vehicle and heavy traffic at 24 hours.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can SC 90 Clear Coat be used outdoors or in areas with UV exposure?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The aliphatic polyaspartic chemistry provides UV stability and non-yellowing performance, making SC 90 suitable for both interior and exterior applications where UV exposure occurs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the pot life of SC 90 after mixing?\u003c\/strong\u003e\u003cbr\u003eA: Pot life is 20–30 minutes for a 100g mass at 77°F \/ 25°C. Pot life decreases with higher temperatures or larger batch sizes, so mix only what can be applied within the working time.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can SC 90 be pigmented?\u003c\/strong\u003e\u003cbr\u003eA: Yes. While SC 90 is available as a clear coat, pigmented options are available upon request.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is SC 90 suitable for immersion service or areas with standing water?\u003c\/strong\u003e\u003cbr\u003eA: No. SC 90 is not intended for immersion service or areas subject to constant water pooling. Consult the technical data sheet and SDS before use in wet environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the coverage rate per gallon?\u003c\/strong\u003e\u003cbr\u003eA: Coverage is 100–150 sq. ft. per gallon per coat, depending on surface porosity and application thickness. At 10 mils wet, coverage is approximately 150 sq. ft.\/gal.\u003c\/p\u003e","brand":"SpecChem","offers":[{"title":"1 gallons","offer_id":67637086847150,"sku":"sc90","price":176.93,"currency_code":"USD","in_stock":true},{"title":"4-1\/2 gallons","offer_id":67637086879918,"sku":"sc90-5","price":657.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0551\/8396\/6382\/files\/SC-90-Clear-Coat.png?v=1791293224","url":"https:\/\/www.diamondtoolstore.com\/products\/sc-90-clear-coat","provider":"Diamond Tool Store","version":"1.0","type":"link"}