Smoke Test Kits, Standard - Standard Smoke Test Kit is backordered and will ship as soon as it is back in stock.
Product Description
Allegro Standard Smoke Test Kit – OSHA-Compliant Qualitative Respirator Fit Testing
The Allegro Standard Smoke Test Kit (Item #2050) is designed for qualitative fit testing of air-purifying respirators in compliance with OSHA's fit testing protocol using stannic chloride smoke. Intended for safety professionals and contractors across painting, manufacturing, oil & gas, and healthcare environments, this kit provides a fast, safe, and easy method to verify respirator fit before each use of a tight-fitting respirator. Each kit includes irritant smoke tubes, an aspirator assembly, and a fit test record form, all housed in a protective carry pouch for convenient field use.
Technical Specifications
| Specification | Details |
|---|---|
| Brand | ALLEGRO |
| Item # | 2050 |
| UPC | 741851205007 |
| Country of Origin | India |
| Smoke Agent | Stannic Chloride (Smoke) |
| Kit Contents | Irritant smoke tubes, aspirator assembly, fit test record form, protective carry pouch |
| Tests Per Tube | Average 3–5 fit tests per tube |
| Use Type | Disposable, one-time use |
| Applications | Painting, Manufacturing, Oil & Gas, Healthcare |
| Technical Tips | Perform fit test before each use of a tight-fitting respirator |
Available Items
| Item # | Description | Size |
|---|---|---|
| 2050 | Standard Smoke Test Kit | Standard Smoke Test Kit |
| 2050-01 | Replacement Tubes, 6/box | Replacement Tubes, 6/box |
Unlike reusable fit testing solutions that carry contamination risk between uses, the Allegro 2050 uses disposable, one-time use glass ampules that make pouring solution into nebulizers easier and reduce the chance of cross-contamination. The stannic chloride smoke agent produces a strong odor that provokes an involuntary reaction—such as coughing—in the test subject, ensuring accurate and objective test results without relying on subjective reporting.
Key Features & Benefits
OSHA-Compliant Fit Testing Protocol
This kit meets OSHA's protocol for qualitative fit testing with smoke, giving contractors and safety managers confidence that their respirator fit testing program satisfies regulatory requirements. Proper documentation is supported by the included fit test record form.
Stannic Chloride Smoke Agent
The emitted tin compound has a strong odor that provokes an involuntary reaction—such as coughing—in the test subject, ensuring test results are objective and accurate. This removes ambiguity from the fit testing process compared to methods that rely solely on the wearer's subjective response.
Disposable, One-Time Use Design
Disposable glass ampules eliminate the risk of contamination between tests, a critical consideration in healthcare and industrial environments. Each tube yields an average of 3–5 fit tests, making the kit cost-effective for small crews or periodic testing programs.
Complete Kit in Protective Carry Pouch
The kit includes irritant smoke tubes, an aspirator assembly, and a fit test record form, all stored in a protective carry pouch for organized, field-ready use. Having all components in one pouch reduces setup time and the risk of missing components on the job site.
Broad Industry Applicability
Designed for use across painting, manufacturing, oil & gas, and healthcare sectors, this kit is versatile enough to support fit testing programs in a wide range of work environments where air-purifying respirators are required.
Common Applications
Painting & Coating Operations
Ensures painters and coating applicators have a properly fitted air-purifying respirator before exposure to solvent vapors and aerosols.
Manufacturing Environments
Supports mandatory respirator fit testing programs in facilities where workers are exposed to airborne particulates, fumes, or chemical vapors.
Oil & Gas Industry
Used to verify respirator fit for workers in environments with potential exposure to hydrocarbon vapors and other hazardous airborne substances.
Healthcare Settings
Enables qualitative fit testing of tight-fitting respirators for healthcare workers requiring protection against airborne pathogens and contaminants.
Compatible Materials
- Air-purifying respirators (tight-fitting)
- Half-face respirators
- Full-face respirators
Frequently Asked Questions
Q: How many fit tests can I perform per tube?
A: Each irritant smoke tube yields an average of 3–5 fit tests.
Q: Are the smoke tubes reusable?
A: No. The tubes are disposable and intended for one-time use to avoid contamination between tests.
Q: Does this kit meet OSHA fit testing requirements?
A: Yes. The Allegro Standard Smoke Test Kit meets OSHA's protocol for qualitative fit testing with smoke.
Q: When should a fit test be performed?
A: A fit test should be performed before each use of a tight-fitting respirator, per the technical guidance provided with this kit.
Q: Can I purchase replacement tubes separately?
A: Yes. Replacement tubes are available as Item #2050-01, sold in a box of 6.