SikaTile - 100 sq. ft. 700 Sound Shield PNS Crack Isolation Sheet Membrane
SikaTile - 100 sq. ft. 700 Sound Shield PNS Crack Isolation Sheet Membrane is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Safe & Secure Payments.
90 Mil Peel And Stick Sound Control And Crack Isolation Sheet Membrane
SikaTile®-700 Sound Shield PNS is a 90 mil (2.3 mm), thin, flexible, self-bonding, fabric reinforced, load-bearing membrane that reduces sound transmission and isolates ceramic and natural stone tile from cracks in the substrate. Suitable for both full and partial coverage applications. SikaTile®-700 Sound Shield PNS reduces the transmission of impact and airborne sound through floors when installed under ceramic tile, stone, or wood floor coverings. It is also a crack isolation membrane that exceeds the requirements of ANSI A118.12 and protects tile from in plane movement up to 3⁄8” (9.5 mm). Its strong self-adhesive backing and uniquely designed surface provide secure bonding for all types of ceramic, natural stone, and terrazzo tile. After application, ceramic tile or stone can be installed immediately using appropriate SikaTile® polymer-modified cement-based mortar. Additionally, glue-down wood flooring can also be installed with approved urethane adhesives.
- Reduces Sound Transmission
- Crack Isolation to 3/8”
- Moisture Vapor Barrier up to 5 lbs. per 1,000 sq. ft in 24 hours
Usage
- Residential (homes, apartments, and condominiums) and commercial (airports, malls, office buildings, restaurants, and galleries) floors, both interior and exterior (with proper drainage)
- Ideal for multi-family or multi-story buildings to reduce noise transmission through floors
Features
- Crack Isolation to 3/8”
- Reduces Sound Transmission
- Moisture Vapor Barrier up to 5 lbs. per 1,000 sq. ft. in 24 hours
- Interior or exterior
- Ideal for multi-family or multi-story buildings to reduce noise transmission through floors
- Mold and mildew resistant
- Dimensions 3 ft. x 33 ft. roll
Suitable Substrates
- Ceramic Tile and Stone
- Cement Backer Board
- Cement Mortar Beds (cured)
- Cement Plaster
- Cement Terrazzo
- Concrete
- Exterior Grade Plywood (interior use only)
- Concrete Masonry
- Lightweight Gypsum Concrete (interior use only)
- SikaLevel Products
1 Consult cement backer board manufacturer for installation recommendations and to verify acceptability for exterior use.
2 Interior Use Only.
Advantages
- Reduces Sound Transmission
- Crack Isolation to 3/8”
- Moisture Vapor Barrier up to 5 lbs. per 1,000 sq. ft in 24 hours
- Easy to position, cut-to-size and install
- Rapid installation - Prime, peel, stick and then immediately install tile, stone, or wood
- Interior or exterior
- Mold and mildew resistant
Packaging
100 sq. ft. per roll; 20 rolls per pallet
Color
White
APPLICATION
Read all installation instructions before installation. Place SikaTile®-700 Sound Shield PNS with release paper still attached over the area to be treated. Unroll the membrane and cut leaving a 2”-3” excess at one end. Roll up ½ of the membrane, leaving the other half unrolled. Cut the release paper from the portion of the membrane and slowly pull the release paper toward you, exposing the tacky surface of the membrane and carefully attaching the membrane onto the primed surface, avoiding wrinkles and bubbles. Repeat the procedure with the unrolled portion of the membrane. Carefully butt edges (overlapping will cause the floor to become uneven). Immediately after installation press membrane into place working out from the center of the membrane by applying heavy pressure with the flat side of a trowel or a 100 lb. roller. Protect exposed membrane from dirt, traffic, and harmful elements until flooring is installed, grouted, and cured.
Finish Surface Installation
Apply finish flooring in compliance with methods of installation over crack-isolation membranes. Do not install any defective, damaged, or any finish flooring surface not for its intended use. The installation of this product does not eliminate the need for movement joints, including perimeter joints with a tiled surface.
SikaTile® elastomeric membranes, when properly installed in accordance with the following installation guidelines, will provide years of protection for finish flooring installations. In addition to these instructions, installers shall also reference the most current edition of American National Standards Institute (ANSI), Tile Council of North America (TCNA) Handbook for Ceramic Tile Installations, The Marble Institute of America (MIA) Dimension Stone Design Manual, NWFA (National Wood Flooring Association) and Manufacturer's instructions of selected setting materials, substrates, sub-floors, or other manufacturers being used in total, or any part of, an installed flooring system with SikaTile®. Consult your selected manufacturer of these above mentioned components to ensure selected products are compatible with SikaTile® elastomeric membranes.
CLEANING OF TOOLS
Clean tools and tile with water before the material dries.